Yesterday I bought four 100W Grape Solar panels from Signature Solar and they were delivered today. They are basically the same panels as the HQST, with a wider border so they're slightly larger). The HQST panels are $69.99 each (279.99 for a set of four), while Signature Solar has them for $49.99 (presumably on clearance). As long as the Grape Solar panels are selling for $49.99, I am going to buy those instead
Left is the HQST panels, right is the Grape Solar:
Voc: ..... 24.30V ....... 23.10V
Isc: ......... 5.21A ......... 5.59A
Vmp: ... 20.40V ....... 19.12V
Imp: ...... 4.91A ......... 5.23A
Left is the HQST panels, right is the Grape Solar:
Voc: ..... 24.30V ....... 23.10V
Isc: ......... 5.21A ......... 5.59A
Vmp: ... 20.40V ....... 19.12V
Imp: ...... 4.91A ......... 5.23A
Category Photography / Miscellaneous
Species Unspecified / Any
Size 2863 x 1287px
File Size 1.75 MB
See that tree on the ground in the background? I cut that down yesterday night so the panels could get more light earlier in the day (they weren't producing more than 100W until after 1PM). The tree fell right onto the 8 panels. Luckily, they didn't break or get damaged.
here's a picture
here's a picture
Yeah, I have a tree I trim come fall so it doesn't block my winter sun.
https://www.furaffinity.net/view/49468293/
Sweep your panels, any little bit can cut how much power you get out of a set.
https://www.furaffinity.net/view/49468293/
Sweep your panels, any little bit can cut how much power you get out of a set.
I have a Victron 150/45 MPPT, you don't want the voltage to max out, as you will release the magic smoke. This MPPT can handle 5 of these in series max, but I prefer the headroom with 4 in series.
Four of these would bring voltage at min temperature (-20C) to 104.9V, and at max temp (60C) to 64.2V. Five would be 131.1V and 81.6V. Four in series would allow for 32 panels (8 strings), Five in series would allow for 30 panels. (6 strings). Per https://www.victronenergy.com/mppt-calculator
I'm currently seeing 82-84V with four in series in the summer heat of Texas (100-105F)
Until I get around to putting these on the roof, I'm going to make a basic tilt system using 2x4's and some carriage bolts w/washers. (Looking at https://diysolarforum.com/threads/p.....t-setup.68971/ )
Four of these would bring voltage at min temperature (-20C) to 104.9V, and at max temp (60C) to 64.2V. Five would be 131.1V and 81.6V. Four in series would allow for 32 panels (8 strings), Five in series would allow for 30 panels. (6 strings). Per https://www.victronenergy.com/mppt-calculator
I'm currently seeing 82-84V with four in series in the summer heat of Texas (100-105F)